RiSec CyberAwareness Logo

CVEs Today

Latest Information on Common Vulnerabilities and Exposures (CVEs)

Last updated: May 31, 2023. 01:20:03

click on an item for more info;

ID Description Modified References
CVE-2021-27196 Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3.0.7. Hitachi ABB Power Grids REB500 7.3; 7.4; 7.5; 7.6; 8.2; 8.3. Hitachi ABB Power Grids RTU500 Series 7.x version 7.x and prior versions; 8.x version 8.x and prior versions; 9.x version 9.x and prior versions; 10.x version 10.x and prior versions; 11.x version 11.x and prior versions; 12.x version 12.x and prior versions. Hitachi ABB Power Grids FOX615 (TEGO1) R1D02 version R1D02 and prior versions. Hitachi ABB Power Grids MSM 2.1.0 versions prior to 2.1.0. Hitachi ABB Power Grids GMS600 1.3.0 version 1.3.0 and prior versions. Hitachi ABB Power Grids PWC600 1.0 versions prior to 1.0.1.4; 1.1 versions prior to 1.1.0.1. May 16, 2023. 21:04:00 [search.abb.com][search.abb.com]
CVE-2018-1168 This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097. May 16, 2023. 21:04:00 [zerodayinitiative.com][library.e.abb.com]
CVE-2018-20720 ABB Relion 630 devices 1.1 before 1.1.0.C0, 1.2 before 1.2.0.B3, and 1.3 before 1.3.0.A6 allow remote attackers to cause a denial of service (reboot) via a reboot command in an SPA message. May 16, 2023. 21:02:00 [search.abb.com][www.securityfocus.com]
CVE-2019-18247 An attacker may use a specially crafted message to force Relion 650 series (versions 1.3.0.5 and prior) or Relion 670 series (versions 1.2.3.18, 2.0.0.11, 2.1.0.1 and prior) to reboot, which could cause a denial of service. May 16, 2023. 21:02:00 [www.us-cert.gov]
CVE-2019-18253 An attacker could use specially crafted paths in a specific request to read or delete files from Relion 670 Series (versions 1p1r26, 1.2.3.17, 2.0.0.10, RES670 2.0.0.4, 2.1.0.1, and prior) outside the intended directory. May 16, 2023. 21:02:00 [www.us-cert.gov]
CVE-2017-15583 The embedded web server on ABB Fox515T 1.0 devices is vulnerable to Local File Inclusion. It accepts a parameter that specifies a file for display or for use as a template. The filename is not validated; an attacker could retrieve any file. May 16, 2023. 20:58:00 [search-ext.abb.com]
CVE-2017-14025 An Improper Input Validation issue was discovered in ABB FOX515T release 1.0. An improper input validation vulnerability has been identified, allowing a local attacker to provide a malicious parameter to the script that is not validated by the application, This could enable the attacker to retrieve any file on the server. May 16, 2023. 20:58:00 [ics-cert.us-cert.gov][www.securityfocus.com]
CVE-2021-22278 A certificate validation vulnerability in PCM600 Update Manager allows attacker to get unwanted software packages to be installed on computer which has PCM600 installed. May 16, 2023. 20:56:00 [search.abb.com][search.abb.com]
CVE-2021-35526 Backup file without encryption vulnerability is found in Hitachi ABB Power Grids System Data Manager – SDM600 allows attacker to gain access to sensitive information. This issue affects: Hitachi ABB Power Grids System Data Manager – SDM600 1.2 versions prior to FP2 HF6 (Build Nr. 1.2.14002.257). May 16, 2023. 20:56:00 [search.abb.com][us-cert.cisa.gov]
CVE-2023-25824 Mod_gnutls is a TLS module for Apache HTTPD based on GnuTLS. Versions from 0.9.0 to 0.12.0 (including) did not properly fail blocking read operations on TLS connections when the transport hit timeouts. Instead it entered an endless loop retrying the read operation, consuming CPU resources. This could be exploited for denial of service attacks. If trace level logging was enabled, it would also produce an excessive amount of log output during the loop, consuming disk space. The problem has been fixed in commit d7eec4e598158ab6a98bf505354e84352f9715ec, please update to version 0.12.1. There are no workarounds, users who cannot update should apply the errno fix detailed in the security advisory. May 16, 2023. 20:54:00 [github.com][github.com]
CVE-2023-32570 VideoLAN dav1d before 1.2.0 has a thread_task.c race condition that can lead to an application crash, related to dav1d_decode_frame_exit. May 16, 2023. 20:48:00 [code.videolan.org][code.videolan.org]
CVE-2019-5620 ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function. May 16, 2023. 20:44:00 [www.rapid7.com]
CVE-2023-27527 Shinseiyo Sogo Soft (7.9A) and earlier improperly restricts XML external entity references (XXE). By processing a specially crafted XML file, arbitrary files on the PC may be accessed by an attacker. May 16, 2023. 20:33:00 [jvn.jp][www.touki-kyoutaku-online.moj.go.jp]
CVE-2021-35527 Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions. May 16, 2023. 20:21:00 [search.abb.com]
CVE-2021-26845 Information Exposure vulnerability in Hitachi ABB Power Grids eSOMS allows unauthorized user to gain access to report data if the URL used to access the report is discovered. This issue affects: Hitachi ABB Power Grids eSOMS 6.0 versions prior to 6.0.4.2.2; 6.1 versions prior to 6.1.4; 6.3 versions prior to 6.3. May 16, 2023. 20:21:00 [search.abb.com]
CVE-2019-19092 ABB eSOMS versions 4.0 to 6.0.3 use ASP.NET Viewstate without Message Authentication Code (MAC). Alterations to Viewstate might thus not be noticed. May 16, 2023. 20:21:00 [search.abb.com]
CVE-2019-19090 For ABB eSOMS versions 4.0 to 6.0.2, the Secure Flag is not set in the HTTP response header. Unencrypted connections might access the cookie information, thus making it susceptible to eavesdropping. May 16, 2023. 20:21:00 [search.abb.com]
CVE-2019-19095 Lack of adequate input/output validation for ABB eSOMS versions 4.0 to 6.0.2 might allow an attacker to attack such as stored cross-site scripting by storing malicious content in the database. May 16, 2023. 20:21:00 [search.abb.com]
CVE-2019-19000 For ABB eSOMS 4.0 to 6.0.3, the Cache-Control and Pragma HTTP header(s) have not been properly configured within the application response. This can potentially allow browsers and proxies to cache sensitive information. May 16, 2023. 20:21:00 [search.abb.com]
CVE-2023-28317 A vulnerability has been discovered in Rocket.Chat, where editing messages can change the original timestamp, causing the UI to display messages in an incorrect order. May 16, 2023. 19:59:00 [hackerone.com]